Getting Help
12-5
Component Update Log
File name: TmuDump.txt
Location:
<Server installation folder>\PCCSRV\Web\Service\AU_Data\AU_Log
To get detailed server update information:
1. Create a file named aucfg.ini with the following content:
[Debug]
level=-1
[Downloader]
ProxyCache=0
2. Save the file to
<Server installation folder>\PCCSRV\Web\Service.
3. Restart the OfficeScan Master Service.
To stop collecting detailed server update information:
1. Delete aucfg.ini.
2. Restart the OfficeScan Master Service.
Client Packager Log
To enable logging for Client Packager creation:
1. Modify ClnExtor.ini in <Server installation
folder>\PCCSRV\Admin\Utility\ClientPackager as follows:
[Common]
DebugMode=1
2. Check ClnPack.log in C:\.
To disable logging for Client Packager creation:
1. Open ClnExtor.ini.
2. Change the "DebugMode" value from 3 to 0.